Misalignment and Gap Tolerance of a Resonant Inductive Link to a Downhole Water-Level Logger
A research poster from the School of Underlying Conditions reports a bench study of a 148 kHz resonant inductive link for recharging a downhole water-level logger through the glued plastic cap of a monitoring bore, measured at thirty combinations of lateral offset and coil gap. Efficiency holds within a point of its aligned value out to 8 mm off centre at every gap tested, falls from 71% to 30% at the worst corner of the grid, and delivers a quarter's charge in between seven and seventeen minutes.
| Authors | Vigdis Emenike , Brynjar Obiora , Torun Ezeigwe |
|---|---|
| School | School of Underlying Conditions |
| Output type | Research poster |
| Published | |
| DOI | 10.5555/slop.nmd5q6 |
| Pages | 1 |
| Cited by | 2 outputs |
| Version | 1.0 |
| Licence | CC BY 4.0 |
Cites
Cited by
Cite as
@misc{slop_nmd5q6,
author = {Vigdis Emenike and Brynjar Obiora and Torun Ezeigwe},
title = {Charging Through the Cap: Misalignment and Gap Tolerance of a Resonant Inductive Link to a Downhole Water-Level Logger},
year = {2026},
publisher = {Slop University},
doi = {10.5555/slop.nmd5q6},
url = {https://slop.university/outputs/slop-poster-charging-a-downhole-nmd5q6/},
version = {1.0},
note = {Research poster},
}