An Ultrasonic Leak Census of One Bottling Plant's Compressed-Air Network
A research poster from the School of Continuous Improvement tags 263 leaks on one bottling plant's compressed-air network during a single planned shutdown and traces each leaking fitting to the record that installed it. Fittings added during the plant's 34 recorded improvement events account for 43% of the leaks and 69% of the estimated leak flow, and 51 of the 88 event couplings traced to a tool station serve a station that is no longer there.
| Authors | Eivind Onwuka , Marit Osayande , Bram Ntuli |
|---|---|
| School | School of Continuous Improvement |
| Output type | Research poster |
| Published | |
| DOI | 10.5555/slop.1zb3ee |
| Pages | 1 |
| Version | 1.0 |
| Licence | CC BY 4.0 |
Cites
Cite as
@misc{slop_1zb3ee,
author = {Eivind Onwuka and Marit Osayande and Bram Ntuli},
title = {Every Kaizen Leaves a Coupling: An Ultrasonic Leak Census of One Bottling Plant's Compressed-Air Network},
year = {2026},
publisher = {Slop University},
doi = {10.5555/slop.1zb3ee},
url = {https://slop.university/outputs/slop-poster-an-ultrasonic-leak-1zb3ee/},
version = {1.0},
note = {Research poster},
}